1: Product function:
24 common functions to meet more application needs; can control C-4 solenoid valve, water pump, motor, lamp
Run freely with waiting
2: Input voltage:
AC 110V~270V (common power supply AC 220V, 110V)
3: Output power:
can control DC or AC load within 5A
4: Time range:
0.01 second to 999 minutes, any time adjustable
5: Wiring port description:
(send trigger wire)
1. Alternating current: input power
2. IN: signal input terminal (negative trigger)
3.NO: The relay is normally open interface, the relay is suspended before it is closed, and it is short-connected to COM after it is closed.
4. COM: relay common interface
5. NC: Relay normally closed interface, short-circuit with COM before the relay is closed, and hang in the air after being closed
6: Function list:
P-11: Jog (to pull in the signal relay, the signal disappears the relay stops)
P-12: Self-locking (switch on the signal relay once, and stop the signal relay again)
P-13: Give the signal, and the relay will automatically stop after closing for A second; triggering is invalid during the delay period
P-14: Give the signal, the relay will stop automatically for A second; trigger to re-timing during the delay period
P-15: Give the signal, the relay will stop automatically for A second; during the delay period, the superposition timer will be triggered
P-16: Give the signal, and the relay will stop automatically for A second; trigger reset during the delay period
P-17: Give the signal, the relay is closed, the input signal is disconnected, the output will be cut off after the timer starts for A second, and it will be given again during the delay period
The signal keeps output and the timing stops
P-18: After the power is turned on, the relay will be closed immediately, and the power will be turned off after a delay of A seconds; until the next time the power is turned on
P-21: Disconnect the signal relay, after a delay of A seconds, the relay will be closed
P-22: Give the signal, after more than A second, the relay is closed, the signal disappears, and the relay stops
P-23: After the signal disappears for more than A seconds, the relay is closed, there is a signal, and the relay stops
P-24: After there is a signal for more than A second, the relay is closed, and after the signal disappears for more than A second, the relay stops
P-25: After the signal is longer than A second, the relay is closed, and after the signal is again longer than A second, the relay stops
P-26: When the signal relay is closed for A second, it stops, and the signal disappears and the relay is closed again for A second and then stops.
P-27: Detect that there is a pulse signal, the relay is closed; if there is no pulse signal, the relay will delay for A second to stop; (the signal continues or
If the signal disappears, it is regarded as no pulse signal)
P-28: After power-on, after a delay of A seconds, the relay will be closed until the power is off
P-31: After power on, the relay is closed for A second, disconnected for B second, infinite loop; power off stops
P-32: When there is a signal, start P-31 infinite loop; when the signal disappears, terminate the loop
P-33: Give a signal to start P-31 infinite loop; give another signal to terminate the loop
P-34: After power-on, the relay will be closed after a delay of A seconds, and stop after being closed for B seconds
P-35: There is a signal, after a delay of A second, the relay will be closed, and the relay will be closed after being closed for B seconds.
P-36: There is a signal, after A second, the relay will be closed, and the relay will be closed after B seconds.
P-37: If there is a signal, the relay will automatically stop for A second when it is closed, and then it will count for B seconds after it stops. The signal trigger is invalid within the time A+B
P-38: When there is a signal, the relay will automatically stop when it is closed for A second, and after stopping and counting for B seconds, it will stop automatically when it is closed again for A second.
7: Button setting instructions:
power-on display "————" means entering the standby state;
Press K1 for the first time (it takes more than 1 second to be effective to prevent false triggering)
Screen display: P-11: K2 adjustment main mode, K3 and K4 adjustment functions
Press K1 for the second time, the screen displays: A001: K2 and K3 adjust the first time A, K4 adjusts the decimal point (time unit)
Press K1 for the third time, the screen displays: B001: K2 and K3 adjust the second time B, K4 adjusts the decimal point (time unit)
Press K1 for the fourth time, the display "————" means it enters the standby state;
Press K4 in standby mode to permanently turn off/on the display and switch to low power consumption mode
8: Decimal point time unit description:
The decimal point of X.XX is in the hundreds, and the timing range: 0.01 seconds to 9.99 seconds
The decimal point of XX.X is in ten's place, timing range: 0.1 second to 99.9 second
XXX has no decimal point, timing range: 1 second to 999 seconds
XXX. The decimal point is in the ones place, and the timing range: 1 minute to 999 minutes
Package Include:
1x Multifunction Digital Display Time Control Relay Delay Module AC110V / 220V 5A
Payment
Shipping
Refund
Payment
We accept PayPal only.
But we only
Accept
your
Ebay Address
,Please Make sure it's 100% right.
Payment must be received in 5 business days of auction closing.
Please leave note for your special request (e.g. Colors or Size) in PayPal when you pay the order.
Any special request cannot be accepted after 24 hours of payment, because most of orders will be processed instantly and same day dispatched.
Shipping
Fill your shipping info
Refund
All package need to
wait 30 days
(US only n
eed 7-10 days)
,
Please take care it.Less than 30 days,we can't take a refund
.
If the item is defect when you receive it or you are not satisfied with it, please return it within 14 days for a replacement or money back. But the items must be back in factory condition. Please contact us and double check the return address before you return it.
If is item is defective in 12 months, you can return it to us. We will send you a new replacement after receiving the defective item.